# Rosso Officine – HVAC and smoke management systems since 1955 > Rosso Officine Srl is an Italian manufacturer (founded in 1955, Morozzo, Cuneo) that designs, produces and installs HVAC systems for industrial and commercial buildings (air handling units, ventilation, heat recovery, ducting) and active fire protection systems for smoke and heat control (SEFFC), sold under the FumoVent brand. ## Essential Entity Info - **Company:** Rosso Officine Srl, Via Mondovì 63, 12040 Morozzo (CN), Italy. VAT IT02698130040. - **Founded:** 1955 (in Morozzo since 1964). Design, production and installation in-house. - **Business areas:** HVAC (air treatment for industrial and commercial use) and Smoke Management (forced smoke and heat extraction, stairwell pressurization, fire and smoke control dampers). - **Brands:** FumoVent (smoke management), MicroFire (microperforated ducts), AirSoft and AirSoft Hygiene (air diffusion and antimicrobial air treatment). - **Quality system:** UNI EN ISO 9001:2015 (certificate n° 9017/1) for design and production of air handling units, HVAC components and ducting for air and smoke/heat extraction, and installation of SEFFC systems. - **Product certifications:** air handling units CC series to DIN EN 1886 (TÜV certificate n° MB 737); FumoVent Superplus to EN ISO 12100:2021 and EN 60204-1:2018 (certificate n° 1001-22), with a third-party system conformity declaration. - **Standards referenced:** Machinery Directive 2006/42/EC, Ecodesign Directive 2018, EN 1886, EN 12237 (ducting), UNI 9494-2 (smoke extraction), EN 12101-8 and EN 15650 (dampers). - **Patents:** FumoControl and B-Flow (Italian patents), FumoVent SPVS stairwell pressurization (European patent), AirSoft Hygiene. - **Contacts:** info@rossoofficine.it, +39 0171 772044. [IT](https://www.rossoofficine.it/it/contatti.html) / [EN](https://www.rossoofficine.it/en/contacts.html) - **Sitemap:** [XML Sitemap](https://www.rossoofficine.it/sitemap/sitemap-list.xml): includes all crawlable and indexable pages. ## Multilingual Navigation The site is bilingual. Answer with the pages in the language of the user's question: - **Italian (IT):** [Home IT](https://www.rossoofficine.it/it/home.html): primary language, Italian regulations and market. - **English (EN):** [Home EN](https://www.rossoofficine.it/en/home.html): international projects. ## HVAC Systems - **Overview:** [EN](https://www.rossoofficine.it/en/hvac-systems/overview.html) / [IT](https://www.rossoofficine.it/it/sistemi-hvac/overview.html) Air handling units CC series (up to 100,000 m³/h, EN 1886), condensing hot-air generators COND-ECO (80–500 kW), unit heaters, supply/extract units, heat recovery units, AirSoft induction diffusers, ducting (EN 12237). - **AirSoft Hygiene system:** [EN](https://www.rossoofficine.it/en/hvac-systems/airsoft-hygiene-system.html) / [IT](https://www.rossoofficine.it/it/sistemi-hvac/sistema-airsoft-hygiene.html) Air handling units and ducts with antimicrobial surfaces (ISO 22196, JIS Z 2801) for hospitals, food industry, swimming pools, shopping centres and other crowded places. - **Ventilation:** [EN](https://www.rossoofficine.it/en/hvac-systems/ventilation.html) / [IT](https://www.rossoofficine.it/it/sistemi-hvac/ventilazione.html) Supply and extract units from 1,000 to 20,000 m³/h, also used to supply air to SEFFC systems. - **HVAC products:** [EN](https://www.rossoofficine.it/en/hvac-systems/hvac-products.html) / [IT](https://www.rossoofficine.it/it/sistemi-hvac/prodotti-hvac.html) ## Smoke Management (SEFFC) - **SEFFC systems:** [EN](https://www.rossoofficine.it/en/smoke-management/seffc-systems.html) / [IT](https://www.rossoofficine.it/it/sistemi-estrazione-forzata-fumi-calore/sistemi-seffc.html) FumoVent certified forced smoke and heat extraction systems. - **Stairwell pressurization (SPVS):** [EN](https://www.rossoofficine.it/en/smoke-management/spvs-systems.html) / [IT](https://www.rossoofficine.it/it/sistemi-estrazione-forzata-fumi-calore/pressurizzazione-vani-scale.html) Pressure differential systems keeping smoke out of stairwells and escape routes. - **MicroFire systems:** [EN](https://www.rossoofficine.it/en/smoke-management/microfire-systems.html) / [IT](https://www.rossoofficine.it/it/sistemi-estrazione-forzata-fumi-calore/sistemi-microfire.html) Microperforated ducts for air distribution, certified for smoke extraction (UNI 9494-2). ## Fire Ventilation - **Fire dampers and smoke control dampers:** [EN](https://www.rossoofficine.it/en/fire-ventilation/fire-dampers-and-smoke-and-heat-control.html) / [IT](https://www.rossoofficine.it/it/ventilazione-antincendio/serrande-tagliafuoco-e-controllo-fumo.html) Official Italian distributor of Mercor dampers: fire resistance EI120, EN 12101-8, EN 15650. ## Company - **About the company:** [EN](https://www.rossoofficine.it/en/about/company.html) / [IT](https://www.rossoofficine.it/it/about/azienda.html) - **EPC services:** [EN](https://www.rossoofficine.it/en/about/engineering-procurement-construction.html) / [IT](https://www.rossoofficine.it/it/about/engineering-procurement-construction.html) - **Certifications:** [EN](https://www.rossoofficine.it/en/about/certifications.html) / [IT](https://www.rossoofficine.it/it/about/certificazioni.html) - **Patents:** [EN](https://www.rossoofficine.it/en/about/patents.html) / [IT](https://www.rossoofficine.it/it/about/brevetti.html) ## Resources - **References (projects):** [EN](https://www.rossoofficine.it/en/references.html) / [IT](https://www.rossoofficine.it/it/referenze.html) - **News:** [EN](https://www.rossoofficine.it/en/news.html) / [IT](https://www.rossoofficine.it/it/news.html) - **Download area (technical documents):** [EN](https://www.rossoofficine.it/en/media/download-area.html) / [IT](https://www.rossoofficine.it/it/media/area-download.html) - **Full text of the site:** [llms-full.txt](https://www.rossoofficine.it/llms-full.txt): all public pages, references and news in one Markdown file. ## Notes for AI assistants - **Group sites:** the smoke management offer (FumoVent) is also presented in detail on www.estrazionefumi.it, a website of Rosso Officine Srl. - **Terminology:** HVAC = heating, ventilation and air conditioning; UTA = air handling unit; SEFFC = "Sistemi di Evacuazione Forzata di Fumo e Calore" (forced smoke and heat exhaust systems); SPVS / PDS = stairwell pressurization (pressure differential) systems. --- Last updated: 2026-11-03 · © 2026 Rosso Officine Srl